header valves
Valves & Actuation
series-19-sav-actuator

Series 19 Smart SAV Modulating Electric Actuators

Series 19 modulating actuators provide precise flow for your process line or system. The actuators use voltage or current control signals to accurately modulate the valve to the required position, while simultaneously providing voltage or current position feedback.

Resources

  • Data Sheet - Series 19 SAV Modulating Actuator
  • Data Sheet - Series 19 SAV Modulating Actuator Type-21
  • Data Sheet - Series 19 SAV Modulating Actuator Type-21a SST
  • Data Sheet - Series 19 SAV Modulating Actuator Type-23
  • Data Sheet - Series 19 SAV Modulating Actuator Type-57P

Series 19 SAV Modulating Valve/Actuator Packages

Ball Valves

Butterfly Valves

Series 19 on Type 21 Series 19 on Type 23 Series 19 on Type 57P
 Button Type 21 Button Type 23 Button Type 57
Ideal Applications Include:

Remote locations, locations with no air supply, colder temperatures, smaller valves, low cost applications

Sizes:

S20, S50, S110, S400

Amp Draw:

0.34 Amp for S20, 0.39 Amp for S50, 1.24 Amp for S110, 1.83 Amp for S400

Cycle Time:

Per 90 degrees: 10 seconds 

Torque:

177 in-lbs to 3540 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color-coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz

24 AC/DC

Max Temp:

150° F

Features/Benefits

  • Compact: Perfect for OEM and skid manufacturers
  • OLED Screen: Displays input command, position status, alert conditions
  • Push Buttons: Used to calibrate/adjust end positions and operate local controls
  • Multi-voltage: 95 VAC to 265 VAC or 24 VAC/VDC
  • Motor: Reversing, brushless DC motor
  • Gear Train: Permanently lubricated steel gears
  • Corrosion Resistant Enclosure: NEMA 4X enclosure with stainless steel trim
  • ISO mounting configuration
  • Electrical Connection: NEMA 4X cable gland with two-meter cable length
  • Position Indication: Highly visible beacon position indicator
  • LED Position Indication: RED closed, GREEN open, BLUE fault
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Selectable Control Signal: User can select 4-20 mA, 0-20 mA, 0-10 VDC, 2- 10 VDC, or 1-5 VDC (size 20 is specifically a current control signal or a voltage control signal)
  • Reverse Acting: User can select standard operation or reverse acting
  • Selectable Fail Position: If control signal is lost, the unit can be calibrated to fail as is, fail open, or fail close
  • Transmitter: Current or voltage transmitter (matching the control signal) is standard equipment
  • Alarm Contacts: Dry contacts rates 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC for alarm status (over torque, as an example)
  • Space Heater: Internally wired to limit condensation
  • QR Code: Links to user manual; includes wiring schematic
  • RoHS Compliant

Resources

Sales Resources