Resources:

Data Sheet

Ideal Applications Include:

CMP Slurry

Specifications:

Flow Ranges:

50 – 500 mL/min
25 – 250 mL/min

Accuracy:

3% S.P.

Repeatability:

1.5% S.P.

Response time:

< 3.0 sec

Shut off speed:

< 3.0 sec

Operating Pressure:

14.5 – 43.5psi

Flush Pressure*:

80 psi

Medium Temperature:

59 – 95° F (15 – 35° C)

End Connections:

1/4” Flare or S300

Voltage:

24 VDC

Current Draw:

0.4 Amp

Output Signals:

4-20mA, 0-5V, 0-10V

Signal Connection:

RS 485

Purge Flow Rate:

20 L/min (ANR)

Purge Connector:

5/32” OD

  • Fast and accurate flow control reduces waste
  • Ultrasonic technology generates precision
  • Straight flow path prevents slurry clogging
  • Dymatrix™ pinch valve provides long life